Step1: Turn off the power and unplug the fryer. Allow the equipment to cool completely.
Step2: Remove the access panel to reach the existing thermostat assembly.
Step3: Disconnect thermostat wires and capillary bulb carefully without bending tubing.
Step4: Unscrew mounting hardware and slide the old thermostat out.
Step5: Position the new thermostat and secure it with screws.
Step6: Reconnect wiring to matching terminals and route the capillary bulb properly.
Step7: Reinstall panels, restore power, and test temperature operation for accuracy.