Anets P5045651-C Natural Gas Safety Control Valve W/ 120 VAC Actuator 3/4" FPT IN/OUT

Special Price CAD$443.18 Regular Price CAD$639.64
In stock
SKU
P5045651-C
The Anets P5045651-C Natural Gas Safety Control Valve is a part with 3/4”FPT inlet and outlet and by 120 VAC actuator. It has up to 300,000 BTU with two reducer bushings for easy installation. This valve works with an eco slotted thermopile magnet for safety measures to be in place and functional. Some of the advantages include, increased safety for the gas appliances, suitability in different fryer models, and easy installation. Its design enables it function properly where it will be required most especially for restaurants and foods service areas.

Dimensions

  • Length: 5.75 In
  • Width: 4.5 In
  • Height: 3.5 In
  • Weight: 2.4 lbs
https://partsfe.com/media/catalog/product/a/n/anets-p5045651-c-natural-gas-safety-control-valve-w-120-vac-actuator-3-4-fpt-in-out-62643.jpg

Product Notes

  • Nat Gas Safety, 3/4" Fpt In/Out, 300.000 Btu, (2) 3/4" X
  • 1/2" Reducer Bushings, 120 Vac Actuator, Blk & Wht Wires,
  • W/Eco Slotted Thermopile Magnet, Model 7000 Bmser-120
  • Thermopile, H231, T-103, # 51-1122, Screw In Type, 7/16-27
  • Brass Pile Holding Nut, 3/8-32 Thread, For Magnet, 750Mv,
  • 500Mv Under Load ,
  • Thermopile, Push On, For Frymaster, # 51-1348.
  • Frymaster Fryer Mac(50,150,250,350), Mj(41,41E,45), Mjcf,
  • Mjcfe. Series: Fm, Mac50.Fmcfe, Fmcfec, J3F, J65X, Jcfx,
  • Kj3Fc,
  • Pitco Fryer Gas Fryers Which Are Rated @ Over 100,000 Btu.
  • Models:24R, 18Wks, 14F
Write Your Own Review
You're reviewing:Anets P5045651-C Natural Gas Safety Control Valve W/ 120 VAC Actuator 3/4" FPT IN/OUT
Your Rating
Customer Questions
What maintenance is required for the Anets P5045651-C Safety Control Valve?

Inspect the Anets P5045651-C Safety Control Valve regularly for gas leaks, dirt, or corrosion. Clean the valve body as needed and ensure all connections are tight to maintain safe operation.

How do I install the Anets P5045651-C Safety Control Valve?

  • Turn off the gas supply and disconnect power to the appliance.
  • Remove the existing safety control valve, noting wire and gas connections.
  • Mount the Anets P5045651-C valve in the designated position on the burner manifold.
  • Connect gas lines securely using approved fittings, ensuring correct orientation.
  • Reattach electrical connections per the wiring diagram.
  • Restore gas and power, then test the valve for proper operation and check for leaks with a soapy water solution.

What are common issues with the Anets P5045651-C Safety Control Valve?

Common issues include sticking due to debris, failure to open/close properly, and leaks at connection points.