Pitco P5045651 Fryer Natural Gas Safety Control Valve W/ 120 VAC Actuator, 3/4" FPT IN/OUT

Special Price CAD$379.93 Regular Price CAD$639.64
In stock
SKU
P5045651
Pitco P5045651 Fryer Natural Gas Safety Control Valve is used to control the correct amount of natural gas is required safely and effectively. This valve has a 120 VAC actuator as well as 3/4” FPT inlet and outlet and operates safely in the kitchen by closing the gas supply if there is a problem with the valve. It is versatile in that it works well with different fryers, easy to install, and can accommodate up to 300,000 BTU, which is suitable for high usage cooking. This valve is essential to control the fryer effectively and to cook food safely at the same time.

Dimensions

  • Length: 5.75 In
  • Width: 4.5 In
  • Height: 3.5 In
  • Weight: 2.4 lbs
https://partsfe.com/media/catalog/product/p/i/pitco-p5045651-fryer-natural-gas-safety-control-valve-w-120-vac-actuator-3-4-fpt-in-out-85566.jpg

Product Notes

  • Nat Gas Safety, 3/4" Fpt In/Out, 300.000 Btu, (2) 3/4" X
  • 1/2" Reducer Bushings, 120 Vac Actuator, Blk & Wht Wires,
  • W/Eco Slotted Thermopile Magnet, Model 7000 Bmser-120
  • Thermopile, H231, T-103, # 51-1122, Screw In Type, 7/16-27
  • Brass Pile Holding Nut, 3/8-32 Thread, For Magnet, 750Mv,
  • 500Mv Under Load ,
  • Thermopile, Push On, For Frymaster, # 51-1348.
  • Frymaster Fryer Mac(50,150,250,350), Mj(41,41E,45), Mjcf,
  • Mjcfe. Series: Fm, Mac50.Fmcfe, Fmcfec, J3F, J65X, Jcfx,
  • Kj3Fc,
  • Pitco Fryer Gas Fryers Which Are Rated @ Over 100,000 Btu.
  • Models:24R, 18Wks, 14F
Write Your Own Review
You're reviewing:Pitco P5045651 Fryer Natural Gas Safety Control Valve W/ 120 VAC Actuator, 3/4" FPT IN/OUT
Your Rating
Customer Questions
What maintenance is required for the Pitco P5045651 Control Valve?

Inspect the Pitco P5045651 regularly for gas leaks, corrosion, or debris. Clean the valve body as needed and ensure connections are tight to maintain safe and reliable operation.

How do I install the Pitco P5045651 Control Valve?

  • Turn off the natural gas supply and power to the appliance.
  • Remove the old safety control valve, noting the orientation and connections.
  • Mount the Pitco P5045651 valve in the designated position on the burner manifold.
  • Connect the gas line securely using approved fittings; check for proper alignment.
  • Reconnect any electrical or pilot components per the wiring diagram.
  • Turn on the gas supply and test the valve for proper operation, checking for leaks with a soapy water solution.

What are common issues with the Pitco P5045651 Control Valve?

Common issues include valve sticking due to debris, failure to open or close properly, and leaks at connection points.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More