Tri-Star 311011 Oven Safety Valve Assembly W/ CCT Adaptors 3/8" FPT

Special Price CAD$762.56 Regular Price CAD$767.27
In stock
SKU
311011
The Tri-Star 311011 Oven Safety Valve Assembly with CCT Adaptors 3/8" FPT functions as a safety mechanism that improves oven system reliability and safety. The valve assembly controls gas flow through automatic shutdown of the supply when system malfunctions occur. The CCT adaptors included in this product design enable simple integration into different installation setups. The valve assembly features 3/8" FPT connections that provide a leak-proof fit and operates efficiently through its design. The valve assembly improves both oven safety and operational efficiency and makes installation and maintenance easier.

Dimensions

  • Length: 3.5 In
  • Width: 3 In
  • Height: 2.5 In
  • Weight: 0.79 lbs
https://partsfe.com/media/catalog/product/t/r/tri-star-311011-oven-safety-valve-assembly-w-cct-adaptors-3-8-fpt-74462-2.jpg

Product Notes

  • 3/8"Fpt, With Cct Adaptors For Each End (One Straight, One
  • 90 Degrees)
  • 3/16" Pilot Cct In/Out With Adjustment Valve On Out
APW WYOTT:
BAKERS PRIDE:
TRI-STAR:
311011, AS-311011, TRS311011
Write Your Own Review
You're reviewing:Tri-Star 311011 Oven Safety Valve Assembly W/ CCT Adaptors 3/8" FPT
Your Rating
Customer Questions
What maintenance is required for the Tri?Star 311011 Safety Valve Assembly with CCT Adaptors?

Periodically inspect the valve assembly for corrosion, leaks, and signs of wear. Check the CCT adaptors for secure attachment and proper torque to avoid gas leaks or loss of seal.

How do I install the Tri?Star 311011 Safety Valve Assembly with CCT Adaptors?

  • Shut off the gas supply and power to the equipment.
  • Remove the existing safety valve assembly, noting how the CCT lines are routed.
  • Clean and prepare the mounting surfaces and threads.
  • Reconnect any capillary tubing, making sure it is routed without sharp bends.
  • Reopen the gas supply and perform a leak test using a gas-safe leak detection fluid.
  • Test burner operation to confirm proper safety shutoff function.

What are common issues with the Tri?Star 311011 Safety Valve Assembly with CCT Adaptors?

Common problems include gas leaks due to loose adaptors, capillary tube damage from kinking, or valve sticking because of corrosion. If the sensing bulb or capillary is bent, the valve may not respond properly to temperature changes.

What operating limitations does the Tri?Star 311011 Safety Valve Assembly with CCT Adaptors have?

This safety valve is designed for gas pressures typical in commercial cooking equipment and should be used within the manufacturer

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More