The Russell 103079-09 Fan Delay Switch is an electrical control part used in residential heating equipment to manage blower fan timing during heating cycles. It regulates when the fan turns on and off based on temperature changes inside a furnace helping coordinate airflow during operation. The unit is commonly installed in furnaces or air handling units where its 2-wire configuration with 15-inch leads allows straightforward connection to existing wiring. It supports consistent heat distribution through ductwork and helps reduce the circulation of unconditioned air at cycle start heating applications.

Dimensions

  • Length: 5 In
  • Width: 3.5 In
  • Height: 1 In
  • Weight: 0.144 lbs
https://partsfe.com/media/catalog/product/r/u/russell-103079-09-2-wire-fan-delay-switch-15-leads-58973-2.jpg

Product Notes

  • Length: 381 mm | 15" Leads
  • Temperature Range: 2 C | 7 C | 35 F Closes | 45 F Opens
  • Type: 2 Wire
MASTERBILT:
RUSSELL:
103079-009, 103079-09, 103079009, RUS103079-009, RUS103079-09, RUS103079009
Write Your Own Review
You're reviewing:Russell 103079-09 Fan Delay Switch 2-Wire 15" Leads
Your Rating
Customer Questions
No Questions

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step 1: Before beginning any service work, ensure that all power to the freezer is disconnected to maintain safety during installation.

Step 2: Identify the current fan delay switch located in the area of the evaporator or control panel.

Step 3: Detach the old switch by removing the two-wire connections from the wiring harness.

Step 4: Verify that the new Russell 103079-09 switch matches the old one to ensure it is the correct component.

Step 5: Attach the leads of the new two-wire fan delay switch to the harness, making certain that the connections are secure and the polarity is correct.

Step 6: Position the switch back in its original mounting location to avoid putting stress on the leads.

Step 7: Reapply power and check the operation of the fan delay by observing the fan's response as temperatures fluctuate.